AUTOCLAVE 20 X 20 MODEL AGE-5196-GMP 1 P OTSA

MXN750,000.00

AUTOCLAVE 20 X 20 MODEL AGE-5196-GMP 1 P OTSA

MXN750,000.00

The Direct and/or Electric Steam Sterilizer (Self-Generated Steam) is a fixed, built-in or cabinet-type equipment that uses saturated steam under pressure as a sterilizing agent. It is ideal for sterilizing laboratory material and objects that resist high temperatures and humidity (wrapped or unwrapped), such as fabrics, surgical instruments, liquids, utensils and other items stable at temperatures from 90° to 140° C.

VAT included
Free Shipping in Mexico**
We ship worldwide

Quote via WhatsApp

AUTOCLAVE 20 X 20 MODEL AGE-5196-GMP 1 P OTSA

Direct Steam and/or Electric Sterilizer (Self-Generated Steam)

Description:

The Direct and/or Electric Steam Sterilizer (Self-Generated Steam) is a fixed, built-in or cabinet-type equipment that uses saturated steam under pressure as a sterilizing agent. It is ideal for sterilizing laboratory material and objects that resist high temperatures and humidity (wrapped or unwrapped), such as fabrics, surgical instruments, liquids, utensils and other items stable at temperatures from 90° to 140° C.

Design and construction:

The chambers (internal and external) and the pressure generator are designed and manufactured with thicknesses according to the ASME code, for boilers and vessels subject to pressure, section VIII, division 1, guaranteeing the safety of the vessels.

Construction of the rectangular chamber:

  • The horizontal sterilizing chamber, rear bottom and surrounding frame are constructed of type 304, 304-L, 316 or 316-L stainless steel plate (as required) in 6.3 mm (1/4”) thickness.
  • The chamber has 1 to 4 ports for validation testing (as required) welded using the inert gas (TIG) process.
  • For 1 or 2 doors, the chamber is built for 3.5 BAR overpressure and full vacuum and guarantees the design, manufacturing and safety of the container.
  • The outer chamber (jacket, chassis and/or steam jacket) is manufactured with a stainless steel plate in the quality required, whether 304, 304-L, 316 or 316-L; in 6.3mm. (1/4”) thick.
  • Frame and front panel in type 304 or 316-L Stainless Steel.
  • It is supplied with thermal insulation of Fiberglass and/or Mineral Wool of 1.25 Lbs. density and in 25.4 mm to 50.8 mm thickness, with aluminum foil cover.

Manual opening doors with security system:

  • Manufactured with 12.7 mm (1/2”) thick Stainless Steel plate and in the quality required, 304, 304-L, 316 or 316-L. And stainless steel cover.
  • Closing by means of radial stainless steel bars which is activated by a handwheel, made of enamelled cast aluminum with polyurethane paint finishes (anti-heat).
  • The lightning core has a diameter of 12.7 cm (5”).
  • The door contains a silicone gasket that allows for an airtight seal and long life.
  • It has an integrated safety system that prevents the door from opening when there is pressure in the chamber during the sterilization period and is deactivated when said pressure is released.
  • Left or right opening with left or right hinge.

Other features:

  • Temperature range: 90° to 140° C.
  • Operating pressure: 2.0 to 3.5 BAR.
  • Automatic temperature and pressure controls.
  • Vacuum system for air removal.
  • Digital timer.
  • Manometer.
  • Security valve.
  • End of cycle alarm.
  • Drain port.
  • Power options: direct steam or electric steam generator.
  • Custom designs and capabilities.

Ratings

There are no reviews yet

Be the first to review “AUTOCLAVE 20 X 20 MODEL AGE-5196-GMP 1 P OTSA”

Your email address will not be published. Required fields are marked with *

FAQ

No questions yet

Ask a question

Your question will be answered by a store representative or other customers.

Thanks for the question!

Your question has been received and will be answered soon. Please don't send the same question again.

Error

Warning

There was an error saving your question. Please report it to the website administrator. Additional Information:

Add an answer

Thanks for the reply!

Your response has been received and will be published soon. Don't send the same response again.

Error

Warning

An error occurred while saving your response. Please report it to the website administrator. Additional Information: