SibelSound 400-AOM Audiometer Cat SIB-01381 Sibelmed
AOM Model Configuration:
- two channels
- Airway liminal tonal audiometry
- Liminal tone bone conduction audiometry
- Masking with narrow band noise
- Masking with white noise
- Synchronized masking
- Selecting scan frequencies
- Continuous and pulsating tone
- Hearing loss calculation
- Diagnosis selectable between different algorithms
- Internal database for more than 1000 tests
- Connection to external printer via USB and parallel
- Connection to computer via USB
- Audiometry Software (Demo)
- Manual and quick guide to use
- Audiometer type according to IEC60645: 3
The SIBELSOUND 400 is a revolutionary two-channel audiometer. The entire system is controlled by a digital signal microprocessor (DSP) that allows, in a reliable, quick and easy way, to carry out an audiometric examination both in the determination of hearing thresholds and 'screening' tests as well as in supraliminar tonal tests.
Features:
- Advanced digital technology using DSP.
- Hearing loss calculation and diagnoses.
- Internal database > 1000 tests.
- Supraliminal evidence.
- High frequency (= 20000Hz).
- Musical Frequencies.
- Automatic masking.
- Connectivity with other management systems.
- Customizable
Technical characteristics
- Channels: Two
- Display: 2 X 16 illuminated alphanumeric LCD
- Protection: Temporary limitation of high signals to protect patient and equipment
- Self-check: Automatically check the status of the audiometer
- Equipment test: Allows the user or technician to verify the status of some functions or elements
- Personalization: Program that allows you to customize the audiometer according to the user's needs
- Calibrations: It has calibrations according to ISO and according to ANSI
- Safety standards: EN60601-1, EN60601-1-1, EN60601-1-2, EN60601-1-4
- Audiometry standards: IEC60645-1, IEC60645-2, IEC60645-4
- Calibration standards: EN ISO 389-1, EN ISO 389-3, EN ISO 389-4, EN ISO 389-5, EN ISO 389-7, ANSI S3.6-2004
- Working temperature: 10 to 40 ºC
- Relative humidity: <90% (non-condensing)
- Power: 100 to 240V ±10% / 50/60 Hz ±3%
- Power: <50VA
- Dimensions: 390mm x 260mm x 105mm
- Weight: 2.4 Kg without accessories
Communications
One of the great qualities of SIBELSOUND 400 is its communications system with other media that allows it to:
- Direct printing to USB printer
- Transfer information from the device's internal database to a PC
- Communicate in real time with a PC
- Export patient tests to other management systems
- Update the internal firmware of the device
- Communications can be carried out, using the corresponding software, through two different channels:
- USB (standard)
Ratings
There are no reviews yet