5 HP QUADRUPLEX 240 gallon medical grade air compressor Cat. PWX-MPQ0508 Powerex
Description:
“Medical Grade” oil-free reciprocating air compressor, air cooled, 5 HP Quadruplex configuration with 240 gallon vertical tank and refrigerant dryers Mod. MPQ0508
- MODEL: MPQ05083K4
- POWER: 20 HP Total (5 HP x 4)
- AIR VOLUME: 55.8 SCFM @ 50 PSIG
- TANK: 240 GALLONS VERTICAL
- VOLTAGE: 230 VOLTS / 60 HZ / 3 PHASES
- REFRIGERATIVE TYPE DRYERS
Features:
- 100% ORIGINAL POWEREX BRAND, MANUFACTURED AND ASSEMBLED IN THE USA
- The medical reciprocating air system is a tank-mounted design consisting of duplex oil-free piston compressors, dual air dryers with purge control, dual filtration system, dew point and CO monitors.
- Hardwired control panel, all mounted in a corrosion resistant air receiver.
- The tank-mounted package is fully integrated into the design and meets current NFPA 99 standards.
- The tank mounted package is provided with single point connections for electrical, air discharge and condensate drains. All systems are operationally tested before shipping.
Oilless Reciprocating Compressor Pump:
- The oil-free reciprocating air compressor pump has a completely oil-free design and does not require oil for operation.
- Composite piston technology, dual cooling fans and sealed bearings provide quality, low-maintenance, oil-free air.
- The pistons are made of heat-repellent composite resin with piston rings constructed of a PTFE material.
- Piston rings have a minimum useful life of 10,000 hours of operation.
- Each compressor will be equipped with the following components:
- Isolation valve, check valve and safety valve.
- ODP electric motor, drive pulley, belts and belt guard.
- Air-cooled aftercooler with moisture separator.
- TMPD (Thermal Malfunction Protection Device)
- Spring insulators.
receiving tankr:
The ASME National Board recorded a working pressure of 200 psig. This horizontal air receiver is equipped with:
- Pressure gauge
- Security valve
- Visual indicator
- Manual and automatic tank drain.
- 3 valve bypass plumbing
- External paint and internal lining to resist corrosion.
Control Panel CONTROL PANELNFPA
- NEMA 12, UL508A listed and labeled with two control transformers with fused primary and secondary circuits.
- The panel has automatic toggle and standby “in use” alarm with visual and audible indicators.
- All alarms have dry contacts on a terminal strip labeled for remote alarms.
- The panel will provide power for the entire system, including all desiccant dryers, drains, monitors and alarms, with a single point electrical connection. Each compressor will be equipped with the following:
- Disconnector.
- Magnetic starter.
- Illuminated HOA switch.
- High temperature stop with visual and audible alarms.
- Hour meter.
Air-cooled aftercoolers:
- Belt guard mounted aftercoolers are provided for each compressor and are sized for an approach temperature of 15ºF.
- The units are constructed of copper tubing with metal headers.
Air purification system:
- Dual refrigerant type air dryers.
- Dual pre filters.
- Dual pressure reducing valves with gauges and safety relief valves.
- Dew point dependent automatic switching to reduce purge frequency.
Monitoring equipment:
- CO monitor with audible/visual alarms and dry contacts for remote alarm signal.
- Dew point monitor with audible/visual alarms and dry contacts for remote alarm signal.
System connections:
- The system is supplied with a remote intake connection and flexible intake and discharge connectors.
- All piping meets current NFPA 99 requirements.
- Insulation pad included.
NOTE: Does not include starting and commissioning
Ratings
There are no reviews yet