300Watts high frequency digital electrosurgery Cat. AAR-IDS310 Bovie
Features:
The Bovie IDS 310 was designed in conjunction with clinicians to provide a safe, easy-to-use generator to meet all operating room procedural performance demands. This innovative energy-based device offers 13 modes of surgical energy delivery. Special modalities include Bovie Advanced Bipolar, Auto Bipolar options, and special laparoscopy modes. These modes were included to assist surgeons in adapting all electrosurgery needs for their variety of surgical applications and user preferences.
- Bovie bipolar – pulsating coagulation for rapid and powerful tissue coagulation
- Auto bipolar – offers immediate and simplified tissue coagulation with minimal tissue damage
- Specialized laparoscopic mode – remembers up to 10 presets and up to 6 bipolar output preferences
- Adjustable energy during activation
Specifications:
Dimensions
- Height: 6.5 in (16.5 cm)
- Width: 14,75 in (37,5 cm)
- Depth: 18,1 in (46 cm)
- Weight: <20 lbs (<9,07 kg)
General Information
- Contact monitoring systems: BovieNEM
- Contact monitoring systems • range/trigger point: 10 ohms or less over all
- Operating range (10C° to 40°C)
- Cooling system: passive cooling
- Technology: isolated RF output
- Pre-set feature: yes
- HP monopolar ports: 2
- Dual activation tone alert: yes
- Power Connector/Switch Ports: Black
Bipolar
- Macro Bipolar
- Watts: 150
- Maximum o Vpeak voltage: 600V
- Crest factor (typical): 1,5 ± 20%
- Frequency: 490kHz ± 4.9kHz
- Micro Bipolar
- Watts: 80
- VPeak Max Voltage: 450V
- Crest Factor (Typical): 1.5 ± 20%
- Frequency: 490 kHz ± 4.9 kHz
- Bipolar Standard
- Watts: 50
- VPeak Max Voltage: 300V
- Crest Factor (Typical): 1.5 ± 20%
- Frequency: 490 kHz ± 4.9 kHz
- Bovie Bipolar
- Watts: 225
- VPeak Max Voltage: 250V
- Crest Factor (Typical): 1.5 ± 20%
- Frequency: 490 kHz ± 4.9 kHz
- Self Bipolar
- Watts: 80
- Frequency: 490 kHz ± 4.9 kHz
monopolar
- Cut I
- Watts: 300
- VPeak Max Voltage: 1000V
- Crest Factor (Typical): 1.7 ± 20%
- Frequency: 490kHz ± 4.9kHz
- Cut II
- Watts: 300
- VPeak Max Voltage: 750V
- Crest Factor (Typical): 1.7 ± 20%
- Frequency: 490kHz ± 4.9kHz
- Blend (1)
- Watts: 200
- VPeak Max Voltage: 1320V
- Crest Factor (Typical): 1.8 ± 20%
- Frequency: 490kHz ± 4.9kHz
- Blend (2)
- Watts: 200
- VPeak Max Voltage: 1475V
- Crest Factor (Typical): 2.0 ± 20%
- Frequency: 490kHz ± 4.9kHz
- Blend (3)
- Watts: 200
- VPeak Max Voltage: 1650V
- Crest Factor (Typical): 2.2 ± 20%
- Frequency: 490kHz ± 4.9kHz
- Blend (4)
- Watts: 200
- VPeak Max Voltage: 1870V
- Crest Factor (Typical): 2.4 ± 20%
- Frequency: 490kHz ± 4.9kHz
- Pinpoint Coagulation
- Watts: 120
- VPeak Maximum Voltage: 1800V
- Crest factor (typical): 3,1 ± 20%
- Frequency: 490kHz ± 4,9kHz
- Spray Coagulation
- Watts: 120
- VPeak Maximum Voltage: 4000V
- Crest factor (typical): 6,0 ± 20%
- Frequency: 350 to 450 kHz
- Gentle coagulation
- Watts: 120
- VPeak Maximum Voltage: 450V
- Crest factor (typical): 1,6 ± 20%
- Frequency: 490kHz ± 4,9kH
Ratings
There are no reviews yet